Case 37
Machines at the far end of the hall drop out on low air pressure at peak times. Compressor swapped for a bigger one. The gauge at the receiver still reads 7 bar when they fault.
Bigger compressor, 7 bar at the receiver, still low at the machines. Where's the pressure going?
A choked filter. The main line filter after the receiver hadn't had its element changed in years. Loaded with oil and dirt, it dropped over a bar at full flow and almost nothing at low flow, so the gauge at the compressor looked perfect while the hall starved. A bigger compressor only pushed harder against the same restriction. Faulty regulators would hit one machine, not the whole far end at once.
The tell: read the pressure either side of the filter at peak demand. A healthy element drops a few tenths of a bar. Much more than that and it's blocked.
Fix: change the element, fit a differential pressure gauge across every main line filter, and change elements on pressure drop, not on the calendar.