The Failure Files · Volume 7

Six more.
The new part was fine.

Component, service history, symptom, photo. You pick what killed it. Then you find out if you're right. Built by a maintenance engineer, for maintenance engineers.

Score 0 / 0
Main line compressed air filter with pressure gauges Case 37
Compressed air main · Packing hall

Machines at the far end of the hall drop out on low air pressure at peak times. Compressor swapped for a bigger one. The gauge at the receiver still reads 7 bar when they fault.

Bigger compressor, 7 bar at the receiver, still low at the machines. Where's the pressure going?

Laser alignment kit on a hot oil pump coupling Case 38
Flexible coupling · Hot oil pump

Pump bearings and coupling elements fail every few months. Laser aligned to a few hundredths of a millimetre at every rebuild. Same again.

Laser aligned perfectly every time. Why is it still failing like it's misaligned?

Inverter drive in a control panel beside a centrifuge Case 39
Inverter drive · Centrifuge

Drive trips on DC bus overvoltage every time the centrifuge is stopped. New drive, same trip. Supply voltage checked and normal.

New drive, normal supply, only trips when stopping. Why?

Every one of these was a call-out someone had to cover

Sickness, a shutdown, a Friday night with a line down and nobody spare. That's the gap Shiftt fills. Vetted engineers, the engineer's rate plus a flat 10%, no agency margin.

See how it works →
Pressure transmitter on a boiler feed line Case 40
Pressure transmitter · Boiler feed line

Pressure on the SCADA reads 0.6 bar high and wanders when the feed pump runs. New transmitter, calibrated on the bench. Same offset.

New transmitter, calibrated, still reads high. What's adding to the signal?

Duty and standby pumps side by side on one base Case 41
Duty and standby pumps · Chilled water

The standby pump's bearings fail within weeks of it going on duty. New bearings at every changeover. They still go, and the duty pump next to it is fine.

New bearings, barely run, still failing. What's killing them?

Distribution board with a tripped motor circuit breaker Case 42
Circuit breaker · Extract fan motor

The breaker trips the instant the fan starts, about one start in three. New breaker of the same rating, same trips. Motor insulation tests fine and it runs at normal current.

New breaker, healthy motor, normal running current. Why does it trip on start?