Case 31
Motor trips on its thermistors during the long slow batches, fine on the fast ones. New motor, same trips. Current is well under the nameplate.
Under nameplate current, new motor, still overheating. Why?
No cooling at low speed. A standard fan cooled motor cools itself with a fan on its own shaft. At 15Hz that fan moves a fraction of its rated air, but the batch still needs close to full torque, so close to full current flows through windings that can't shed the heat. Current under nameplate means nothing once the cooling has gone. Dragging bearings would show at every speed. A low supply trips the drive, it doesn't cook the motor.
The tell: heat that follows speed, not load. Feel the air coming off the cowl at low speed, then at full speed.
Fix: fit a separately powered cooling fan to the motor, or size the motor for the torque it needs at its lowest running speed. Check the maker's derating curve for continuous running below half speed.