Case 19
Laser aligned and signed off last month. Vibration is back, the coupling insert is chewed, and a cold recheck shows it out again.
Aligned perfectly, out again within weeks. Why won't it hold?
Soft foot. One motor foot sat proud of the baseplate. Torquing it down sprang the frame, so the motor was bolted on under strain from day one. Run it, heat it, shake it, and a sprung frame relaxes and creeps. Thermal growth would have shown hot and come back cold. This was out cold.
The tell: alignment that won't repeat. Put a dial on the shaft and slacken one foot bolt at a time. Any foot that moves it more than 0.05mm is soft.
Fix: check for soft foot before you align, every time. Shim the soft foot flat, recheck all four, then align and torque in sequence.